Description
ProTaper Next® Flexible performance
THE ProTaper® PHILOSOPHY REMAINS
- A SINGLE FILE SEQUENCE FOR MOST CLINICAL CASES
- VARIABLE TAPERS FOR OPTIMIZED CROWN-DOWN TECHNIQUE
- APPROVED APICAL FINISHING DIAMETERS
The next generation of the endo reference
ProTaper Next® is the successor to the ProTaper® Universal system, which has been the gold standard in endodontics for many years. It is an efficient*
solution for endo practitioners seeking a versatile, flexible system that will handle the vast majority of root canal treatments.
The next generation covers more difficult clinical cases
The unique swaggering movement and the greater flexibility of the ProTaper Next® files make it possible to shape more severely curved narrow canals than what was possible before with most NiTi systems on the market.
The next generation brings improved safety
The risk of file breakage is significantly decreased, at the same time, respect of the original root canal anatomy is greatly improved. Instrument performance and patient safety are- essential to good endodontics.
The next generation shortens the shaping time*
A shorter clinical sequence means that less time is spent changing instruments. The high cutting efficiency also reduces the shaping time. For the dentist, this is valuable time that can be used for other procedures, such as irrigation.
The next generation improves debris removal
The unique off-centred rectangular cross section gives the file a snake-like swaggering movement and provides enlarged space for the debri.
Motor Settings: 300 rpm / 2 - 5.2 Ncm
ProTaper Next® XA (Accessory)
Recommended for preflaring the orifice, removing triangles of dentin, relocating the coronal aspect of a canal away from an external root concavity, and creating more shape as desired.
Dentsply Sirona Endodontics advocates medical standard care by packaging ProTaper Next® files in pre-sterilised blister packs for single patient use. Using two to three ProTaper Next® shaping files for each clinical procedure, instead of four to five previously, makes it affordable for the practitioner to implement a single use policy for endodontic instruments with numerous advantages, namely:
Ergonomics
There is no need for reprocessing and re-organising ProTaper Next® NiTi files.
Reduced risk of file breakage
Endodontic files are subject to cyclic fatigue, which is the main cause of file breakage during endodontic treatment. This
increases dramatically with multiple use. Single use therefore reduces the risk of file breakage and thus increases patient safety
Optimal cutting efficiency
Using endodontic files for multiple cases actually reduces their cutting efficiency, affecting the performance and satisfaction for both dentist and patient. With ProTaper Next®, the cutting efficiency stays the same as a new
instrument is used for each patient.
No risk for cross contamination
No matter how well an instrument is reprocessed, research shows that certain bacteria and tissue remnants may remain on the instrument. Additional uses of instruments* therefore increase the potential of cross-contamination to
every subsequent patient.
0 Review for “ProTaper Next® | Endodonitic Files”
5 Stars
0%
4 Stars
0%
3 Stars
0%
2 Stars
0%
1 Stars
0%